Adres: 1235. CADDE (ESKİ 58) 18
Tel 1: 0 (312) 385 11-73
Tel 2: 0 (312) 385 11-74
Faks: 0 (312) 354 31-67
Email 1: ildam@ildam.com.tr
Email 2: selami@ildam.com.tr
Web: www.ildam.com.tr
pH and Conductivity Meter (Multiparameter) Table Type -2,000 - 20,000 pH | 0.001 µS/cm - 1000 mS/cm METTLER TOLEDO S213-K
Model | S213-K (Kit) |
Set Content | S213 Multiparameter, electrode holder, protective cover, user manual, instructions for use, CE certificate and test certificates, 2 x pH 4.01, 7.00, 9.21, 10.00 buffer solution, 2 x 1413µS/cm, 12.88 mS/cm calibration solution, pH – conductivity measurement theory book |
Set Electrodes | Inlab Expert Pro – ISM pH Electrode (30014096) and Inlab 731-ISM Conductivity Electrode (30014092) |
Device Type | Table Type Multiparameter Device |
Measurement Parameters | pH; ORP; Conductivity; TDS; Salinity; Resistivity; Conductivity Ash |
Measuring Range (pH) | -2,000…20,000 |
Measurement Resolution (pH) | 0.001 / 0.01 / 0.1 |
Measurement Linearity (pH) | +-0.002 |
Measuring Range (mV & rel.mV) | -20,000…20,000 |
Measurement Resolution (mV & rel.mV) | 0.1 / 1 |
Measurement Linearity (mV & rel.mV) | Between -1000…+1000 +-0.1 mV / outside +-0.2 mV |
Measuring Range (EC) | 0.001 µS/cm…1000 mS/cm |
Measurement Resolution (EC) | 0.001…1 |
Measurement Linearity (EC) | +-0.5% |
Measuring Range (TDS) | 0.00 mg/L…1000 g/L |
Measurement Resolution (TDS) | 0.01…1 |
Measurement Linearity (TDS) | +-0.5% |
Measuring Range (Salinity) | 0.00…80.00 psu |
Measurement Resolution (Salinity) | 0.00…1.0 |
Measurement Linearity (Salinity) | +-0.5% |
Measuring Range (Resistance) | 0.00…100.0 MΩcm |
Measurement Resolution (Resistance) | 0.00…1.0 |
Measurement Linearity (Resistance) | +-0.5% |
Measuring Range (Conductivity Ash) | 0.000…2022% |
Measurement Resolution (Conductivity Ash) | 0.001…1 |
Measurement Linearity (Conductivity Ash) | +-0.5% |
Temperature Compensation Range | -5.0…+130.0°C (MTC -30.0°C) |
Temperature Compensation Resolution | 0.1°C |
Temperature Compensation Linearity | +-0.1°C |
calibration | |
Calibration Points | Max 5 points |
pH Buffer Group | 8 predefined and 1 user defined |
Conductivity Buffer Group | 13 predefined or 1 user defined |
Pad Recognition | Automatic |
Isopotential Point | pH 7.00 |
Temperature Reading | Automatic and Manual |
Calibration Reminder | User defined |
Electrode Status Icon | Quality and final calibration icon |
Cell Constant | By Calibration or Manual entry |
Measurement | |
Fixing Type | Automatic, Manual, Time Controlled |
Stabilization Criteria | Fast, Standard, Solid |
pH Decimal Position | X.XXX, X.XX, XX |
Temperature Reading | Automatic and Manual |
Serial Measurements | User defined time control |
System and GLP | |
Menu Help | 12 language options |
Display and Color Chart | blue, red, green, gray |
Time and Date | 2 hours, 4 date formats |
PIN Protection | Login, edit data, edit system |
Measurement Limits | User defined |
Device Modes | Routine mode, Expert mode |
ID Input | User ID, Sample ID, Sensor ID, Sensor SN |
ID Input Automation | Barcode reader and keyboard (USB) |
Data processing | |
Data Storage | 2000 measurements |
Print Formats | short, normal, GLP |
Data Export | USB Stick, EasyDirect pH software |
Links | |
pH Sensor Input | BNC (impedance > 3×1012 Ω) |
pH Temperature Sensor Input | Cinch/RCA (NTC30 kΩ or Pt1000) |
Reference Input | 2mm Ref. |
Conductivity Sensor Input | Mini-DIN |
Conductivity Temperature Sensor Input | Mini-DIN (integrated into conductivity input) |
Connection Interfaces | RS232, USB-A, USB-B |
Mixer Connection | Mini-DIN |
general | |
Power Requirement | DC 9-12V/10W |
Size/Weight | 204x174x74mm, 890g |
Screen | TFT |
Ambient conditions | |
Heat | 5…40°C |
Relative humidity | 5…80% |
Installation Category | II |
Pollution Degree | 2nd |
Altitude | From sea level up to 2000m |
Protection Class IP 54 | |
Materiel | |
Outer Case | ABS/PC reinforced |
Screen | Polymethyl methacrylate (PMMA) |
Keyboard | Membrane keypad (PET) |