Cat-C Cable Vertical Flame Resistance Tester

Cat-C Cable Vertical Flame Resistance Tester

Experimental Cell
- Combustion cabinet in accordance with TS EN 60332-3-10 standard
-Internal dimensions 100x200x400 ± 10 cm
-Practical placement of the experimental ladder with the crane attached to the top of the cell
-Sample ladder (thin and optionally thick)
-Air flow fan (1060 m3/h)
-Production from AISI 304 quality 2mm thick stainless steel
- Glass wool with a coefficient of 0.7 Wm-2.K-1 is used for insulation
-Burn and Venturi

Control unit
-The control unit controls the burner (gases and ignition) and the air flow fan
-Air and Propane Mass Flow Meter (Mass Flow Controller) controlled
-Automatically start and apply the test with the touch industrial computer

Get Info