AquaTest T10

Aquatest T10

Features
.Innovative combination of electronic amplifier and test strip without tangling
.ergonomic design guarantees effortless operations
.Sturdy construction for outdoor use
.On-site rechargeable batteries
.Significant noise quality, the use of high-performance microphone technology
.Special visualization of noises on the display, with operator support
.No disruptive operation noise on earphones due to new type of sensor area
.Personal adjustment of filter bands and level/hearing protection settings for optimal noise identification
Two different product options are available with or without .SDR radio module

PHYSICAL WATER LEAK DETECTION DEVICES

MAIN CAUSES OF PHYSICAL WATER LEAK:

* High Water Pressure

* Poor quality of pipe material

* Small pipe diameter

* Poor workmanship on fittings

* Rotting of the pipe by aging

* Soil features and collapses

* Heavy traffic load

* Water quality

* Various repair activities

* Carelessly made meter and service connections

* Abandoned links.

WORKING PRINCIPLE:

Physical water leaks in the world are generally made by using acoustic listening method by listening to the vibrations and vibrations on the pipe with sensitive microphones. Technological developments have provided convenience in water leak detection as in many sectors.

WHERE TO USE:

After testing in all city networks with water at a certain pressure, indoor installations, heating installations, natural gas and oil lines, if there is a leak, it can be listened to by giving pressurized water into the line.

WHY USED:

When there is a water leak, it is not possible to find where the leak is. It is necessary to dig every suspected spot, but even this method is not always and everywhere possible and takes a lot of time. It is not an effective method either. Here, physical water loss detection devices come into play and lead us to the leak without any excavation, allowing us to find its exact point.

RULES TO BE CONSIDERED WHEN USING ON THE FIELD:

One of the most important things we need to pay attention to is whether there is an external sound that will affect the device where we hear excessive noise and we suspect that the settings / values of the device are correct.

TIPS OF WATER LEAK DETECTION:

We need to concentrate fully on the device and we should stop working in situations that will damage our ears.

We should use different microphone feet according to the characteristics of the ground. (For example, using soil stakes on soft soils)

We cannot listen properly in noisy environments. By making the most efficient listening during the night hours when the pressure in the networks is the highest and the external noises are the least, we can reach the result with better quality and faster.

EXAMPLES:

It is one of the examples experienced today that the water escaping from the pipes hollows the ground and causes collapses, seeps into the foundations of the buildings, rots the foundations and causes the buildings to collapse.

AquaTest T10

The AquaTest T10 is a test stick with innovative technology and ergonomic design. It demonstrates appropriate proficiency in locating leaks in water pipe networks. The AquaTest T10 is the first test strip made by SEWERIN to require no additional receiver.


The earphones are activated not by a public switch, but by a special sensor area. On a combined indicator with the handle, results are visualized and noises are separated. With the SDR radio frequency module, in different products, the test stick can be used with radio frequency headphones. This means that too many cables are not used.

Basic application-Location

The AquaTest T10's high-quality microphone technology allows for first-class sensitivity in noise discrimination. Even the smallest leaks are reliably detected by the test rods. In the case of using the test rod, it can be easily screwed between the search tip and the microphone. It also helps in the personal improvement of acoustic results according to the choice of one of eight different frequency bands.

In noise flow operation, sampling can be done by simply placing a cap on the sensor area. This cancels out the disturbances caused by operational noises in the earphones while listening. The Aquatest T10 instrument panel displays current and previous minimum noise levels, as well as current noise intensity. Minimum noise levels are shown as numerical values; Current noise intensity is shown as a bar graph. This gives already less experienced operators visual support as to whether they are approaching a leak.

Additional applications-Leak and acoustic pipe location detection

With the AquaTest T10, the leaks detected as a location can also be detected. For this, the search tip is put back in place with a tripod. This separates the noise of the leak at the surface. If the pipe is under vibration, the position of the pipe can be determined using AquaTest T10, by using the installation, COMBIPHON system features such as blocker or stopper. This includes systematically surface testing in short steps. The noise level increases as you approach the vibrating pipeline. The noise is highest directly above the pipe.

Scope of delivery

Aquatest T10
· Headphones
· Search tip
· Chargers
· Carrying bag

Optional accessories
· Tripod
Expansion devices for the search tip