Homepage ›› Companies ›› Enermak Energy Mak. And İnş. Singing. Trade Ltd. Sti. ›› IFX-A IFX-B IFX-C

Enermak Energy Mak. And İnş. Singing. Trade Ltd. Sti.

Adres: 1234. CADDE (ESKİ 57) 125

Tel 1: 0 (312) 385 11-02

Tel 2: 0 (312) 240 55-54

Faks:

Email 1: info@enermak.com

Web: https://www.enermak.com/

IFX-A IFX-B IFX-C

Ifx-A Ifx-B Ifx-C

ISOFLUX

ISOFLUX ultrasonic Flow meters, A full range Directional meter, single-Beam OR Double-Beam, Conductive, Non-conductive Flowmeters for measurements of aggressive liquids. The Range Includes the following Versions:

IFX-A - AC power meter

IFX-B - Battery Power meter

IFX-C - water meters approved ARA

Ultrasonic Transition Works According to the principle of Ultrasonic Flow meters Waves moving against the direction of Liquid Flow in the Measuring Visit in Times difference. Meter sensor related, Occurs electronic Unit A.Ş. Flow. Added offer excellent HIGH Measurement accuracy over Wide User Value Range of measured values, long-term credits stability, negligible Hydraulic Losses Ultrasonic Flow meter measuring Capability of almost clean's liquid Flow Rate in its visit.
The Electronic Unit provides power to both ultrasonic probes and its outputs via its Flow Rate Communication to other equipment processing systems in Information. The Meter is Available as either a System (battery) OR Compact with Remote Electronic Unit (AC Power).

IFX-A

Ultrasonic Flowmeter

Counter features

The material of sensor measuring part made of stainless steel, carbon steel 1.4301, flange and cover

6000 Green RAL Painting

DN300 nominal diameter DN32 (up to DN 800 on request)

Nominal pressure PN16, PN40

Measurement accuracy IFX-A1X: 1% ±> 0.5 m/s for liquid v velocity

IFX-A2X: 0.5% ± 0.5 m/s for liquid v velocity >

Current up to flow profile sensitivity class: 5XD (IFX-A2X) or 10xD (IFX-A1X) - downstream: 3xD (IFX-A2X) or 5XD (IFX-A1X)

Liquid 0-150 ° C temperature

Ambient temperature 5 electronics +55 ° C

Display unit alphanumeric LCD unit, 2 lines, 16 characters each

230V AC Power supply 90, 50 60Hz

Protection class IP65 electronics, sensor IP68

Outputs (isolated) pulse type, 1,000Hz or 10kHz relay type 24VAC / 0.1 A 0.1 One pulse per 1,000 liters frequency type, 0

Optional accessories communication line RS 485 Current output 0 (4) 20mA. Flow measurement in Twodirections

IFX-B

Ultrasonic Flowmeter

Counter features

The material of sensor measuring part made of stainless steel, carbon steel 1.4301, flange and cover

6000 Green RAL Painting

DN300 nominal diameter DN32

Nominal pressure PN16, PN40

Measuring accuracy class 2 according to EN 14154

Stream up to profile sensitivity class Stream: 5XD (IFX-B2) or 10xD (IFX-B1) - downstream: 3xD (IFX-B2) or 5XD (IFX-B1)

Liquid, temperature 0-50 ° C

Ambient temperature 0-50°C

Display unit alphanumeric LCD unit, 2 lines, 16 characters each

Power supply Li battery 3.6 V / 19Ah - life time 8 years

Protection class sensor and electronics IP68

Outputs passive pulse output (U = 3 30V, I = 10mA 1, timp = 30ms)

20mA passive current output 4 (U = 10 24V)

Optional equipment bidirectional measurement, RS232 or RS232 + USB converter



IFX-C

ultrasonic flowmeter

Features

• Certified according to MID (European metrology certificate) and OIML R49

• Designed in accordance with the standard EN14154

• Fresh water and/or mechanical water meters designed for substitution measurement of the WOLTMAN type

• Can measure instantaneous flow rate, water consumption and pressure in both directions

• Moving part

• Very low pressure losses



Counter features

Cast iron sensor material

Green RAL 6000 or Blue Rylsan WRAS approved painting

DN200 nominal diameter DN32

Measuring accuracy class 2 according to EN 14154

Connection Flanges (EN, ANSI, JIS)

Nominal pressure PN16

Temperature class: Class T30

Stream up to profile sensitivity class Stream: 5XD (IFX-C2) or 10xD (IFX-C1) - downstream: 3xD (IFX-C2) or 5XD (IFX-C1)

Liquid, temperature 0-50 ° C

electromagnetic environment E1, E2

Display unit single line 8 character LCD display

Flow rate sampling period 1 sec

Protection class sensor and electronics IP68

20mA Output passive current output 4 - (U = 10 24 V) passive pulse output (U = 3 30V, I = 1 for 10mA, timp = 30ms)

Optional equipment bidirectional measurement, RS232 or RS232 + USB converter

Get Info