Application
Sensitive coatings with a thickness of up to 2 mm such as Epoxy, Rilsan, etc. or even foil can be safely tested with ISOTEST motion DC (direct current voltage). Pores, even weak points are precisely detected cracks.
All ISOTEST ® holiday detectors have undergone extensive testing in the field of safety and EMC. All of them carry the CE label and fulfill all relevant standards and technical requirements (DIN EN / ISO / DVGW etc.)
You can count on...
a compact "all-in-one" device (control unit and high voltage generator in one compact body)
Suitable for continuous operation (three shifts)
Porosity/leakage testing of all non- or slightly conductive materials
structured menu and touch panel provide easy operation
current values and changes made are displayed on the screen
Precise filter settings allow an optimal adjustment of sensitivity to different testing requirements
Test voltage with external on/off intelligent light curtain control
test current limitation test provides maximum safety for personal
Continuous test voltage – even under the toughest operating conditions – guaranteed by processor-controlled, load-dependent energy control
Reliable test results even at extremely high test speeds
detection and visualization thanks to the integral evaluation process, even the smallest pores or imperfections
technical data
Test voltage: 0.5 - max 0.1 kV, negative current, 6.0 kV in DC (effective value) steps. 1.0 mA (per channel)
Test channels: 1, 2 or 4 test channels optionally
Voltage supply: 100 - 240 VAC / 47 - 63 Hz (Wide input range)
Power supply (load dependent): <100 W
Entries:
test voltage external activation
with key contact or 24 VDC
Outputs floating on change for pore alarm
floating contact without pore alarm
Inverter floating for operational monitoring
Working time: three shifts
Test speed: up to 1000 mm / s
Test voltage regulation: load dependent adaptation (continuous)
Selectable filter settings to perfectly match individual test conditions: load adaptation
Porosity Indication:
Visual signal on the screen
potential free contact for external signaling units
Other viewing options:
pore counter
multilingual menu
test time indicator (current and total)
next scheduled service date indicator
Permissible ambient temperature: 0 °C ... +50 °C (thermal constant> 10 K / h)
Air humidity: max. 60% relative air humidity at 30°C
Scope of delivery:
in-plant holiday detector ISOTEST motion DC
high voltage cable
Software ISO Audit
works / calibration certificate
User guide
Features
Non-destructive holiday detection with maximum test reliability and minimum material stress
• Adjustable sensitivity and filter functions
Data backup via USB interface
• Up to 4 separate test channels
Speed test up to 1000 mm / s
•External on / off smart light barrier control with test voltage